HP Insight Management WBEM Providers 9.2 SNMP Data Migration Guide
Table 2466
ValueTrap Variable
1.3.6.1.4.1.232.8023Trap OID
cpqSsExBackplaneTempStatusChangeTrap OID Name
HPSA_DeviceIndication HPSCSI_DeviceIndication
HPSAS_DeviceIndication
Indication Class
“HP Smart Array”, “HP SCSI”, “HP SAS”Indication ProviderName
“308”Indication EventID
Implemented in Smart Array, SCSI and SAS providers See
profiles for details
Notes
Table 2467
ValueTrap Variable
1.3.6.1.4.1.232.8024Trap OID
cpqSsExBackplanePowerSupplyStatusChangeTrap OID Name
cpqSs5PwrSupplyStatusChangeIndication Class
HPSA_DeviceIndication HPSCSI_DeviceIndication
HPSAS_DeviceIndication
Indication ProviderName
“HP Smart Array”, “HP SCSI”, “HP SAS”Indication EventID
“301”, “302”, “303”Notes
Table 2468
ValueTrap Variable
1.3.6.1.4.1.232.8025Trap OID
cpqSsExRecoveryServerStatusChangeTrap OID Name
Not ImplementedIndication Class
Indication ProviderName
Indication EventID
Notes
Table 2469
ValueTrap Variable
1.3.6.1.4.1.232.8026Trap OID
cpqSs5FanStatusChangeTrap OID Name
HPSA_DeviceIndication HPSCSI_DeviceIndication
HPSAS_DeviceIndication
Indication Class
“HP Smart Array”, “HP SCSI”, “HP SAS”Indication ProviderName
“304”, “305”, “306”Indication EventID
Implemented in Smart Array, SCSI and SAS providers See
profiles for details
Notes
446 Storage Trap to Indication Mappings