HP Insight Management WBEM Providers 9.2 for Microsoft® Windows® Data Sheet
4-3-19 HP_Location
HP_Location is used to model power supply locations on ProLiant servers. The Windows®
implementation class is HP_WinPowerSupplyLocation.
Table 2-20 Class: HP_Location
Property name
Property implementation
CIM_ManagedElement
Caption Power Supply n, where n represents the power supply
position printed on the system labeling.
Description The location of the power supply n. Please refer to
power supply position n printed on the system.
ElementName Power Supply n, where n represents the power supply
position printed on the system labeling.
CIM_Location
Name Unique identifier for this power supply location
instance
PhysicalPosition n, where n represents the power supply position
printed on the system.
HP_Location
ElementLocationTag Power Supply n, where n represents the power supply
position printed on the system.
ElementLocationTagDesc
0 (HoodTag)
4-3-20 HP_ElementLocation
HP_ElementLocation is used to represent an association between CIM_Location and
CIM_ManagedElement. The Windows® implementation class is
HP_WinPowerSupplyElementLocation.
Table 2-21
Class: HP_ElementLocation
Property name
Property implementation
Element
References CIM_ManagedElement
PhysicalLocation
References CIM_Location
4-3-21 CIM_ConfigurationCapacity
CIM_ConfigurationCapacity is used to model power supply configuration capacity on ProLiant
Servers. The Windows® implementation class is HP_WinPowerSupplyConfigurationCapacity.