HP Insight Management WBEM Providers 9.2 for Microsoft® Windows® Data Sheet

3-4-2 Processor Deconfigured
Table 1-21 HP_ProcessorHardwareIndication: Processor Deconfigured
Property name
Property implementation
CIM_Indication
IndicationIdentifier
GUID string generated at the time of indication
PerceivedSeverity
4 (Minor)
IndicationTime
Time of indication
CIM_AlertIndication
Description A processor has been disabled by ROM Based Setup
(RBSU).
AlertingManagedElement
WBEM Path of the HP_ProcessorChip instance
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID
2
EventTime Time of the event or time of the indication if event time
unknown
ProviderName
HP Processor
RecommendedActions Check processor configuration and replace processor if
necessary.
SystemName
HP_ComputerSystem.SystemName
SystemCreationClassName
HP_ComputerSystem.CreationClassName
HP_AlertIndication
Summary
Processor deconfigured
EventCategory
2 (Processor)
ProbableCause
1 (Other)
ProbableCauseDescription
Processor Deconfigured
ProviderVersion Provider version generating the indication in the
format, <major>.<minor>.<revision>.<build>
NetworkAddresses Contains a list of all the IP addresses (IPv4 and IPv6) of
the computer system generating the indication
OSType
For Windows 2003 32-bit: 69
For Windows 2003 64-bit: 70
For Windows 2008 32-bit: 76
For Windows 2008 64-bit: 77
For Windows 2008 R2: 103