HP Insight Management WBEM Providers 9.2 for Microsoft® Windows® Data Sheet

Table 1-34 HP_SATADeviceIndication: Disk Drive status Degraded
Property name
Property implementation
Description
A Disk Drive status has changed to Degraded.
AlertingManagedElement
WBEM path of the HP_SATADiskDrive class
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID
604
ProviderName
HP SATA
RecommendedActions Check status of physical drive. Degraded status may
be caused by failed or missing physical drive, or due
to a data recovery operation on the physical drive.
SystemName
Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary
Disk Drive status Degraded
EventCategory
6 (Primary Storage Device)
ProbableCause
35 (Performance Degraded)
ProbableCauseDescription
Disk Drive State Changed to Degraded
NetworkAddresses Contains a list of all the IP addresses (IPv4 and IPv6) of
the computer system generating the indication
OSType
For Windows 2003 32-bit: 69
For Windows 2003 64-bit: 70
For Windows 2008 32-bit: 76
For Windows 2008 64-bit: 77
For Windows 2008 R2: 103
OSVersion Operating system version of the computer system
generating the indication in the format,
<major>.<minor>.<build>
ProviderVersion Provider version generating the indication in the
format, <major>.<minor>.<revision>.<build>
SystemFirmwareVersion Firmware version of the computer system generating
the indication
SystemSerialNumber Serial number of the computer system generating the
indication
SystemProductID Product ID of the computer system generating the
indication
SystemModel Model name of the computer system generating the
indication