HP Insight Management WBEM Providers 9.2 for Microsoft® Windows® Data Sheet

Table 1-81 HPSCSI_DeviceIndication: Fan status change - ERROR
Property name
Property implementation
EventID
16
ProviderName
HP SCSI
RecommendedActions Check your fan subsystem as soon as possible.
Continued operation can cause failure of the drives.
SystemName
Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary
SCSI Storage enclosure fan is failed
EventCategory
24 (Primary Storage Cooling)
ProbableCause
94 (Fan Failure)
ProbableCauseDescription
Fan Failure
ProviderVersion Provider version generating the indication in the
format, <major>.<minor>.<revision>.<build>
NetworkAddresses Contains a list of all the IP addresses (IPv4 and IPv6) of
the computer system generating the indication
OSType
For Windows 2003 32-bit: 69
For Windows 2003 64-bit: 70
For Windows 2008 32-bit: 76
For Windows 2008 64-bit: 77
For Windows 2008 R2: 103
OSVersion Operating system version of the computer system
generating the indication in the format,
<major>.<minor>.<build>
SystemFirmwareVersion Firmware version of the computer system generating
the indication
SystemSerialNumber Serial number of the computer system generating the
indication
SystemProductID Product ID of the computer system generating the
indication
SystemModel Model name of the computer system generating the
indication
SystemGUID Platform GUID of the computer system generating the
indication
ImpactedDomain
3 (Enclosure) for c-Class BladeSystems
4 (System) for all other systems
When ImpactedDomain is 3 (Enclosure), the properties
indicated with (*) are populated.