HP Insight Management WBEM Providers 9.2 for Microsoft® Windows® Data Sheet

ThresholdValue
A string holding the current value of the warning
threshold
ObservedValue
A string holding the current reading value that
exceeds the threshold
HP_ThresholdIndication
EventCategory
106 0x6a (System)
NetworkAddresses Contains a list of all the IP addresses (IPv4 and IPv6)
of the computer system generating the indication
OSType
For Windows 2003 32-bit: 69
For Windows 2003 64-bit: 70
For Windows 2008 32-bit: 76
For Windows 2008 64-bit: 77
For Windows 2008 R2: 103
OSVersion Operating system version of the computer system
generating the indication in the format
<major>.<minor>.<build>
ProviderVersion Provider version generating the indication in the
format, <major>.<minor>.<revision>.<build>
Summary
Disk Warning threshold exceeded
SystemModel Model name of the computer system generating the
indication
SystemProductID Product ID of the computer system generating the
indication
SystemSerialNumber Serial number of the computer system generating the
indication
HP_DiskThresholdIndication
2-4-13 Threshold Indication - Disk Utilization Critical Threshold
Exceeded
Table 2-15
HP_ThresholdIndication: Disk Utilization Critical Threshold Exceeded
Property name
Property implementation
CIM_Indication
IndicationIdentifier
GUID string generated at indication
PerceivedSeverity
5 (Major)
IndicationTime
Time of indication
CIM_AlertIndication
Description The Disk utilization critical threshold has exceeded for
Disk:(Disk Name)
AlertingElementFormat
1 (Unknown)
AlertType
1 0x1 (Other)
EventID
1