HP Insight Management WBEM Providers 9.2 for Microsoft® Windows® Data Sheet
Table 1-76 HPSCSI_DeviceIndication: Temperature sensor status change OK
Property name
Property implementation
HWLogicalLocation
Enclosure Location string
HWSerialNumber
Enclosure Serial Number
HP_DeviceIndication
DeviceModel
Enclosure Model string
17-4-16 Temperature sensor status change Warning Condition
Table 1-77 HPSCSI_DeviceIndication: Temperature sensor status change Warning Condition
Property name
Property implementation
CIM_Indication
IndicationIdentifier
GUID string generated at indication
PerceivedSeverity
4 (Minor)
IndicationTime
Time of indication
CIM_AlertIndication
Description The SCSI Storage enclosure temperature is outside of
normal operating range
AlertingMangedElement WBEM path of the HPSCSI_StorageEnclosureProcessor
class instance
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID
24
ProviderName
HP SCSI
RecommendedActions Ensure server cover is properly installed. Ensure all
empty disk drive bays are filled with drive covers.
SystemName
Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary This SCSI Storage enclosure temperature status is
Warning
EventCategory
24 (Primary Storage Cooling)
ProbableCause
51 (Temperature unacceptable)
ProbableCauseDescription
Temperature Status Changed to Warning Condition