HP Insight Management WBEM Providers 9.2 for Microsoft® Windows® Data Sheet
HP_CPUThresholdIndication
2-4-12 Threshold Indication - Disk Utilization Warning Threshold
Exceeded
Table 2-15 HP_ThresholdIndication: Disk Utilization Warning Threshold Exceeded
Property name
Property implementation
CIM_Indication
IndicationIdentifier
GUID string generated at indication
PerceivedSeverity
3 (Degraded/Warning)
IndicationTime
Time of indication
CIM_AlertIndication
Description The Disk utilization Warning threshold has exceeded
for Disk:(Disk Name)
AlertingElementFormat
1 (Unknown)
AlertType
1 0x1 (Other)
EventID
2
ProviderName
HP Disk Threshold
RecommendedActions
None
SystemName
HP_ComputerSystem.Name
SystemCreationClassName
HP_ComputerSystem.CreationClassName
ProbableCause
1 0x1 (Other)
ProbableCauseDescription
Disk Warning threshold exceeded
SystemFirmwareVersion Firmware version of the computer system generating
the indication
SystemGUID Platform GUID of the computer system generating the
indication
ImpactedDomain
•
3 (Enclosure) for c-Class BladeSystems
•
4 (System) for all other systems
When ImpactedDomain is 3 (Enclosure), the
properties indicated with (*) are populated.
BladeBay *
HP_BladeCSLocation.LocationInformation[0]
BladeName *
HP_ComputerSystem.Name
EnclosureName *
HP_BladeEnclosureCS.Name
RackName *
Rack name if one exists
RackUID *
Rack Unique Identifier if one exists
SystemVirtualSerialNumber Conditional property containing the virtual system
serial number string when running in a Virtual
Connect environment
SystemVirtualUUID Conditional property containing the virtual system
UUID when running in a Virtual Connect environment
CIM_ThresholdIndication