HP Insight Management WBEM Providers 9.2 for Microsoft® Windows® Data Sheet

Table 2-96 HPSAS_DeviceIndication: Enclosure Fan status changed to Failure
Property name
Property implementation
AlertType
5 (Device Alert)
EventID
306
EventTime Time of the event or time of the indication if event time
unknown
ProviderName
HP SAS
RecommendedActions Ensure that the system is adequately ventilated. Check
for proper room temperature and internal/external
airflow. Add or repair fans and air baffling if
necessary.
SystemName
Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary
Fan status Error
EventCategory
24 (Primary Storage Cooling)
ProbableCause
94 (Fan failure)
ProbableCauseDescription
Fan Failure
ProviderVersion Provider version generating the indication in the
format, <major>.<minor>.<revision>.<build>
NetworkAddresses Contains a list of all the IP addresses (IPv4 and IPv6) of
the computer system generating the indication
OSType
For Windows 2003 32-bit: 69
For Windows 2003 64-bit: 70
For Windows 2008 32-bit: 76
For Windows 2008 64-bit: 77
For Windows 2008 R2: 103
OSVersion The operating system version of the computer system
generating the indication in the format:
<major>.<minor>.<build>
SystemFirmwareVersion Firmware version of the computer system generating
the indication
SystemSerialNumber Serial number of the computer system generating the
indication
SystemProductID Product ID of the computer system generating the
indication
SystemModel Model name of the computer system generating the
indication
SystemGUID Platform GUID of the computer system generating the
indication