HP Insight Management WBEM Providers 9.2 for Microsoft® Windows® Data Sheet
Table 2-87 HPSAS_DeviceIndication: Logical Drive is in a degraded state
Property name
Property implementation
ImpactedDomain
•
3 (Enclosure) for c-Class BladeSystems
•
4 (System) for all other systems
When ImpactedDomain is 3 (Enclosure), the properties
indicated with (*) are populated.
BladeBay *
HP_BladeCSLocation.LocationInformation[0]
BladeName *
HP_ComputerSystem.Name
EnclosureName *
HP_BladeEnclosureCS.Name
RackName *
Rack name if one exists
RackUID *
Rack Unique Identifier if one exists
SystemVirtualSerialNumber Conditional property containing the virtual system
serial number string when running in a Virtual Connect
environment
SystemVirtualUUID Conditional property containing the virtual system
UUID when running in a Virtual Connect environment
SolutionProductModel
Conditional property containing the Solution Name
string when running in a aggregate product
environment in the format <aggregate product family
name> v<major>.<minor>.<update>
2-4-12 Enclosure Power Supply status changed to Non
Redundant
Table 2-88
HPSAS_DeviceIndication: Enclosure Power Supply status changed to Non Redundant
Property name
Property implementation
CIM_Indication
IndicationIdentifier
GUID string generated at the time of indication
PerceivedSeverity
3 (Warning)
IndicationTime
Time of indication
CIM_AlertIndication
Description A Storage Enclosure Power Subsystem status has
changed to non-redundant.
AlertingMangedElement
WBEM Path of HPSAS_StorageEnclosureProcessor
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)