Table 2-78 HPSAS_DeviceIndication: SAS HBA in Error state
Property name
Property implementation
CIM_Indication
IndicationIdentifier
GUID string generated at the time of indication
PreceivedSeverity Severity
• 5 (Major)
IndicationTime
Time of indication
CIM_AlertIndication
Description
A SAS/SATA HBA status has changed to Error.
AlertingMangedElement
WBEM Path of controller
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID
2
EventTime Time of the event or time of the indication if event time
unknown
ProviderName
HP SAS
RecommendedActions
Replace the HBA.
SystemName
Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary
HBA status Error
EventCategory
11 (I/O Adapter)
ProbableCause
2 (Adapter/Card Error)
ProbableCauseDescription
HBA Status Changed to Error
ProviderVersion Provider version generating the indication in the
format, <major>.<minor>.<revision>.<build>
NetworkAddresses Contains a list of all the IP addresses (IPv4 and IPv6) of
the computer system generating the indication
OSType
•
For Windows 2003 32-bit: 69
•
For Windows 2003 64-bit: 70
•
For Windows 2008 32-bit: 76
•
For Windows 2008 64-bit: 77
• For Windows 2008 R2: 103
OSVersion The operating system version of the computer system
generating the indication in the format: