HP Insight Management WBEM Providers 9.2 for Microsoft® Windows® Data Sheet

Table 1-120 HPSA_DeviceIndication: Controller Redundancy state has been set to ACTIVE
Property name
Property implementation
HP_HardwareIndication
HWFirmwareVersion
Array Controller firmware version string
HWLogicalLocation Array Controller Location string
For example, Smart Array P600 in Slot 5
HWManufacturer
Array Controller Manufacturer string
HWSerialNumber
Array Controller Serial Number
HP_DeviceIndication
DeviceModel
Array Controller Model string
15-4-13 Controller Redundancy has been lost
Table 1-121 HPSA_DeviceIndication: Controller Redundancy has been lost
Property name
Property implementation
CIM_Indication
IndicationIdentifier
GUID string generated at indication
PerceivedSeverity
3 (Warning)
IndicationTime
Time of indication
CIM_AlertIndication
Description Controller has detected that Redundancy has been lost
due to failure or loss of communication with partner
controller.
AlertingMangedElement
WBEM path to the HPSA_ArrayController class.
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID
4
ProviderName
HP Smart Array
RecommendedActions
Check status of partner Array Controller.
SystemName
Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary
Controller Redundancy has been lost
EventCategory
6 (Primary Storage)