Table 1-42 HPSA_DeviceIndication: Physical Drive status changed to PREDICTIVE FAILURE
Property name
Property implementation
HWPhysicalLocation
Physical Location of the Failed Drive (Bay Number)
DeviceControllerLogicalLocation Controller Location
For example, SmartArray 642 in Slot 2
HWManufacturer
HP
HWSerialNumber
Physical Disk Serial Number
HP_DeviceIndication
DeviceModel
Physical Disk Model string
15-4-5 Physical Drive Status Changed to PREDICTIVE
FAILURE – Solid State Wear Out
Table 1-113
HPSA_DeviceIndication: Physical Drive status changed to PREDICTIVE FAILURE
Property name
Property implementation
CIM_Indication
IndicationIdentifier
GUID string generated at indication
PerceivedSeverity
5 (Major)
IndicationTime
Time of indication
CIM_AlertIndication
Description Due to Solid State wear out a physical drive status has
changed to Predictive Failure .
AlertingMangedElement
WBEM path of the HPSA_DiskDrive class
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID
204
ProviderName
HP Smart Array
RecommendedActions
Replace drive immediately to avoid loss of data
SystemName
Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary
Physical Drive status is now PREDICTIVE FAILURE
EventCategory
6 (Primary Storage)