HP Insight Management WBEM Providers 9.2 for Microsoft® Windows® Data Sheet

Table 1-4 Class: HPSA_StorageVolume (CIM_StorageVolume)
Property name
Property implementation
NameFormat
2 (VPD83NAA6)
PackageRedundancy
0 (RAID 0)
1 (RAID 1+0, RAID 5, RAID 1 (ADM), RAID 1+0
(ADM))
2 (RAID 6, RAID 50)
CIM_Storagevolume
HPSA_Storagevolume
Accelerator
See HP Smart Array Profile
Deleteable
See HP Smart Array Profile
FaultTolerance
See HP Smart Array Profile
OSName Corresponding OS name for this volume.
If the volume/logical disk failed, then this variable d
displays empty
StripeSize
See HP Smart Array Profile
Identify()
See HP Smart Array Profile
PhysicalDrvMultipathAccess Uint16 PhysicalDrvMultipathAccess Value
Valuemap
1 (not supported)Not supported by Array
Firmware
2 (not configured)Supported by Array Firmware
but not configured
3 (configured redundant)Volume is configured
with redundant physical paths on all physical
drives
that make up the volume
4 (configured non-redundant)Volume is
configured with redundant paths but is currently not
redundant possibly due to failure of 1 or more
paths or a configuration error
Primordial
FalseCan create and delete this element
15-3-4 HPSA_DiskDrive
HPSA_DiskDrive represents the Hard Drives connected to Smart Array controllers.
Table 1-5 Class: HPSA_DiskDrive (CIM_DiskDrive)
Property name
Property implementation
CIM_ManagedElement
Description Interface Type of the Physical Drive
e.g: SAS