HP Insight Management WBEM Providers 9.2 for Microsoft® Windows® Data Sheet
Table 1-26 HP_AlertIndication: Ethernet Team Redundancy Increased
Property name
Property implementation
SystemVirtualSerialNumber Conditional property containing the virtual system
serial number string when running in a Virtual Connect
environment
SystemVirtualUUID Conditional property containing the virtual system
UUID when running in a Virtual Connect environment
SolutionProductModel Conditional property containing the Solution Name
string when running in a aggregate product
environment in the format <aggregate product family
name> v<major>.<minor>.<update>
13-4-3 Ethernet Team Redundancy Decreased
Table 1-27 HP_AlertIndication: Ethernet Team Redundancy Decreased
Property name
Property implementation
CIM_Indication
IndicationIdentifier
GUID string generated at indication
PerceivedSeverity
3 (Degraded/Warning)
IndicationTime
Time of indication
CIM_AlertIndication
Description The Ethernet Team has transitioned from Fully
Redundant or Degraded Redundancy to Degraded
Redundancy due to a failed or degraded team
member.
AlertingManagedElement WBEM path of the Ethernet Team
(HP_WinEthRedundancySet) reporting decreased
redundancy
AlertingElementFormat
2 (CIMObjectPath)
AlertType
2 (Communications Alert)
Event Id
4
ProviderName
HP Ethernet
RecommendedActions[] View the Ethernet and Ethernet Team Member status in
the HP Network Configuration Utility (NCU).
View the System Event Log for additional information.
SystemCreationClassName CreationClassName of the computer system generating
the indication