HP Insight Management WBEM Providers 9.2 for Microsoft® Windows® Data Sheet

Table 1-24 HP_SensorHardwareIndication: Fan Redundancy Reduced
Property name
Property implementation
ImpactedDomain
3 (Enclosure) for c-Class BladeSystems
4 (System) for all other systems
When ImpactedDomain is 3 (Enclosure), the properties
indicated with (*) are populated.
BladeBay *
HP_BladeCSLocation.LocationInformation[0]
BladeName *
HP_ComputerSystem.Name
EnclosureName *
HP_BladeEnclosureCS.Name
RackName *
Rack name if one exists
RackUID *
Rack Unique Identifier if one exists
SystemVirtualSerialNumber Conditional property containing the virtual system
serial number string when running in a Virtual Connect
environment
SystemVirtualUUID Conditional property containing the virtual system
UUID when running in a Virtual Connect environment
SolutionProductModel Conditional property containing the Solution Name
string when running in a aggregate product
environment in the format <aggregate product family
name> v<major>.<minor>.<update>
HP_HardwareIndication
HWSerialNumber Conditional property containing the chassis serial
number when the chassis is a multi-node server chassis
5-4-7 Fan Redundancy Lost
Table 1-25
HP_SensorHardwareIndication: Fan Redundancy Lost
Property name
Property implementation
CIM_Indication
IndicationIdentifier
GUID string generated at indication
PerceivedSeverity
4 (Minor)
IndicationTime
Time of indication
CIM_AlertIndication
Description Cooling redundancy has been lost.
(RedundancySetCaption), where RedundancySetCaption
represents the HP_WinCoolingRedundancySet.Caption
for the redundancy set that lost redundancy.