HP Insight Management WBEM Providers 9.2 for Microsoft® Windows® Data Sheet
5-4-2 Fan Inserted
Table 1-20 HP_SensorHardwareIndication: Fan Inserted
Property name
Property implementation
CIM_Indication
IndicationIdentifier
GUID string generated at indication
PerceivedSeverity
2 (Information)
IndicationTime
Time of indication
CIM_AlertIndication
Description A fan has been inserted. (FanCaption), where
FanCaption is the HP_WinFan.Caption for the fan that
has been inserted
AlertingManagedElement WBEM path of the HP_WinFan instance representing
the inserted fan
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID
2
ProviderName
HP Cooling
RecommendedActions
No action is recommended.
SystemName
HP_ComputerSystem.Name
SystemCreationClassName
HP_ComputerSystem.CreationClassName
HP_AlertIndication
Summary
Fan Inserted
EventCategory
23 (System Cooling)
ProbableCause
1 (Other)
ProbableCauseDescription
Fan Inserted
ProviderVersion Provider version generating the indication in the
format, <major>.<minor>.<revision>.<build>
NetworkAddresses Contains a list of all the IP addresses (IPv4 and IPv6) of
the computer system generating the indication
OSType
•
For Windows 2003 32-bit: 69
•
For Windows 2003 64-bit: 70
•
For Windows 2008 32-bit: 76
•
For Windows 2008 64-bit: 77
• For Windows 2008 R2: 103
OSVersion Operating system version of the computer system
generating the indication in the format,
<major>.<minor>.<build>