HP Insight Management WBEM Providers 9.2 for Microsoft® Windows® Data Sheet

Table 1-8 Class: HP_HostedCoolingCollection
Property name
Property implementation
Antecedent
References HP_ComputerSystem
Dependent
References HP_CoolingCollection
5-3-8 HP_SystemFan
HP_SystemFan is used to represent an association between HP_Fan and the computer system that
contains this fan. The Windows® implementation class is HP_WinSystemFan.
Table 1-9 Class: HP_SystemFan
Property name
Property implementation
GroupComponent
References HP_ComputerSystem
PartComponent
References HP_Fan
5-3-9 HP_FanModule
HP_FanModule is used to model the physical fans on ProLiant Servers. The Window-specific
implementation class is HP_FanModule.
NOTE:
Fan numbers for existing instances do not change when other fans are added and removed.
Table 1-10 Class: HP_FanModule
Property name
Property implementation
CIM_ManagedElement
Caption Fan n, where n represents the number of the fan
instance
Description Fan n provides cooling for FanType. StatusDescription
where n represents the number of the fan instance,
FanType represents the corresponding string value of
the FanType enumeration and StatusDescription
represents the value of StatusDescriptions[0]
ElementName Fan n, where n represents the number of the fan
instance
CIM_Managed SystemElement
OperationalStatus[0]
2 (OK)If fan is operating properly
6 (Error)If fan has failed
StatusDescriptions[0]
Fan is operating properly”If
OperationalStatus[0] is 2 (OK)
“Fan has failed”If OperationalStatus is 6 (Error)