HP Insight Management WBEM Providers 9.1 for Windows Server 2008 Event Log Messages Reference Guide

5 Sample Indication and Log Message
Here is a sample of a Windows Event Log message from an indication with a Source of “HP
Sensor” and an Event ID of “6”.
Figure 2 Windows Event Log message
Description expanded from above:
Cooling redundancy has been lost. (Cooling Redundancy Set 1)
User Action
Check the fan configuration and check the status of the cooling redundancy. Ensure the system is being cooled
adequately. Add or replace fans if necessary.
WBEM Indication Properties
AlertingElementFormat: 2 0x2 (CIMObjectPath)
AlertingManagedElement:
"\\ARSENAL\root\HPQ:HP_WinCoolingRedundancySet.InstanceID="HPQ:HP_WinCoolingRedundancySet:1""
AlertType: 5 0x5 (Device Alert)
Description: "Cooling redundancy has been lost. (Cooling Redundancy Set 1)"
EventCategory: 23 0x17 (System Cooling)
EventID: "6"
ImpactedDomain: 4 0x4 (System)
IndicationIdentifier: "{001B63B4-CE51-4E6A-AEF1-3C3D8F9F91EE}"
IndicationTime: "20080320131649.812000-300"
NetworkAddresses[0]: "192.168.1.11"
OSType: 77 0x4D (Microsoft Windows Server 2008 64-Bit)
OSVersion: "6.1.7600"
PerceivedSeverity: 4 0x4 (Minor)
ProbableCause: 88 0x58 (Loss of Redundancy)
ProbableCauseDescription: "Cooling Redundancy has been Lost"
ProviderName: "HP Cooling"
ProviderVersion: "9.0"
RecommendedActions[0]: "Check the fan configuration and check the status of the cooling redundancy. Ensure the
system is being cooled adequately. Add or replace fans if necessary."
Summary: "Cooling redundancy lost"
SystemCreationClassName: "HP_WinComputerSystem"
SystemFirmwareVersion[0]: "2008.01.24"
SystemFirmwareVersion[1]: "2007.06.28"
SystemGUID: "34373134-3535-5532-5837-303930374839"
8 Sample Indication and Log Message