Table 2 Insight Provider Indications for Version 9.1 (continued)
Windows
Event ID
(short)
Windows
Event ID (full)
Windows
Event
Source
DescriptionSummaryEvent IDProvider Name
1023221225574
HP Smart
Array
A logical drive
status has
changed to Error.
Logical drive
status error102
HP Smart
Array
1032147483751
HP Smart
Array
A logical drive is
in a degraded
Logical drive
in degraded
state103
HP Smart
Array
state. Device is
still servicing I/O
but redundancy
may be degraded
or lost.
1042147483752
HP Smart
Array
A logical drive is
in a degraded
Logical drive
in degraded
104
HP Smart
Array
state. Multipath
state -
support is Lost.
multipath
failure
Either cable is
removed or not
configured.
2011073742025
HP Smart
Array
A physical drive
status has
Physical
Drive status
OK201
HP Smart
Array
changed from a
non-OK state to
OK.
2023221225674
HP Smart
Array
A physical drive
status has
changed to Error.
Physical drive
status Error202
HP Smart
Array
2031073742027
HP Smart
Array
A physical drive
status has
Physical drive
is now
rebuilding.203
HP Smart
Array
changed to
Rebuilding. Data
is now being
rebuilt onto this
drive from the
RAID set.
2043221225676
HP Smart
Array
A physical drive
status has
Physical drive
status
204
HP Smart
Array
changed to
Predictive Failure.
Predictive
Failure.
2052147483853
HP Smart
Array
A Physical Drive is
Currently Offline
Physical drive
status Secure
Erase.205
HP Smart
Array
but operational,
Secure Erase is in
Progress. Once
the Secure Erase
is Complete,
please reinsert the
same disk or new
disk for the disk to
be operational.
2061073742030
HP Smart
Array
A physical drive is
in Online state.Physical
Drive status
Online206
HP Smart
Array
After Secure Erase
Operation
3012147483949
HP Smart
Array
A Storage
Enclosure Power
Power Supply
status
Non-Redundant301
HP Smart
Array Subsystem status
24 List of HP Insight Provider Indications