HP Insight Management WBEM Providers 9.1 for Windows Server 2008 Event Log Messages Reference Guide
Table 2 Insight Provider Indications for Version 9.1 (continued)
Windows
Event ID
(short)
Windows
Event ID (full)
Windows
Event
Source
DescriptionSummaryEvent IDProvider Name
changed to Fully
Redundant.
3032147483951HP SAS
A Storage
Enclosure Power
Power supply
status
303HP SAS
Supply status has
Redundant
Degraded
changed to
Degraded
Redundancy.
3041073742128HP SAS
A Storage
Enclosure Fan
Fan status
OK304HP SAS
status has
changed from a
non-OK state to
OK.
3052147483953HP SAS
A Storage
Enclosure Fan
Fan status
Degraded305HP SAS
status has
changed to
Degraded. An
enclosure has
detected there
may a problem
with one or more
of the fans.
3063221225778HP SAS
A Storage
Enclosure Fan
Fan status
Error306HP SAS
status changed to
Failure. An
enclosure has
detected a failure
in the fan
subsystem and
there is insufficient
fan capability to
ensure normal
operation.
3071073742131HP SAS
A Storage
Enclosure
Temperature
sensor status
OK307HP SAS
Temperature
sensor status
changed from
non-OK to OK.
3082147483956HP SAS
A Storage
Enclosure
Temperature
sensor status
308HP SAS
Temperature
Warning
Condition
sensor status
changed to
Warning
Condition. This
indicates the
enclosure
temperature is
above normal,
otherwise
enclosure is still
operating
normally.
18 List of HP Insight Provider Indications