HP Insight Management WBEM Providers 9.1 for Windows Server 2008 Data Sheet

Table 2-20 Class: HP_Location
Property name Property implementation
ElementName Power Supply n, where n represents the power supply
position printed on the system labeling.
CIM_Location
Name Unique identifier for this power supply location
instance
PhysicalPosition n, where n represents the power supply position
printed on the system.
HP_Location
ElementLocationTag Power Supply n, where n represents the power supply
position printed on the system.
ElementLocationTagDesc 0 (HoodTag)
4-3-20 HP_ElementLocation
HP_ElementLocation is used to represent an association between CIM_Location and
CIM_ManagedElement. The Windows® implementation class is
HP_WinPowerSupplyElementLocation.
Table 2-21 Class: HP_ElementLocation
Property name
Property implementation
Element References CIM_ManagedElement
PhysicalLocation References CIM_Location
4-3-21 CIM_ConfigurationCapacity
CIM_ConfigurationCapacity is used to model power supply configuration capacity on ProLiant
Servers. The Windows® implementation class is HP_WinPowerSupplyConfigurationCapacity.
There is one instance of this class on systems modeling power supply configuration capacity.
Table 2-22
Class: CIM_ConfigurationCapacity
Property name
Property implementation
CIM_ManagedElement
Caption Power Supply Configuration Capacity
Description This describes the number of power supplies that can
be configured.
ElementName Power Supply Configuration Capacity
CIM_PhysicalCapacity