HP Insight Management WBEM Providers 9.1 for Windows Server 2008 Data Sheet
Table 2-15 Class: HP_PowerMeter
Property name Property implementation
CIM_EnabledLogicalElement
EnabledDefault 2 (Enabled)
EnabledState 5 (Not Applicable)
RequestedState 12 (Not Applicable)
CIM_Sensor
SensorType
13 (Power Consumption)
CurrentState “Normal”
PossibleStates Array may contain the following value:
PossibleStates[9] = ”Normal”
CIM_NumericSensor
CurrentReading Current reading of the power meter
BaseUnits 7 (Watts)
RateUnits
0 (None)
UnitModifier 0
SupportedThresholds <empty>
SettableThresholds
<empty>
HP_PowerMeter
4-3-15 HP_AssociatedPowerMeter
Table 2-16 Class: HP_AssociatedPowerMeter
Property name Property implementation
CIM_Dependency
CIM_ AssociatedSensor
HP_AssociatedPowerMeter
Antecedent ref: HP_PowerMeter
Dependent ref: HP_PowerSupply
4-3-16 CIM_SoftwareIdentity
CIM_SoftwareIdentity describes power controller firmware. The Windows®-specific implementation
class is HP_ PowerControllerFirmware. The following properties are implemented.