Table 1-20 HP_ProcessorHardwareIndication: Processor Failed
Property name Property implementation
ImpactedDomain
•
3 (Enclosure) for c-Class BladeSystems
•
4 (System) for all other systems
When ImpactedDomain is 3 (Enclosure), the properties
indicated with (*) are populated.
BladeBay * HP_BladeCSLocation.LocationInformation[0]
BladeName * HP_ComputerSystem.Name
EnclosureName * HP_BladeEnclosureCS.Name
RackName * Rack name if one exists
RackUID * Rack Unique Identifier if one exists
SystemVirtualSerialNumber Conditional property containing the virtual system
serial number string when running in a Virtual Connect
environment
SystemVirtualUUID Conditional property containing the virtual system
UUID when running in a Virtual Connect environment
SolutionProductModel
Conditional property containing the Solution Name
string when running in a aggregate product
environment in the format <aggregate product family
name> v<major>.<minor>.<update>
3-4-2 Processor Deconfigured
Table 1-21 HP_ProcessorHardwareIndication: Processor Deconfigured
Property name
Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at the time of indication
PerceivedSeverity 4 (Minor)
IndicationTime Time of indication
CIM_AlertIndication
Description A processor has been disabled by ROM Based Setup
(RBSU).
AlertingManagedElement
WBEM Path of the HP_ProcessorChip instance
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 2
EventTime Time of the event or time of the indication if event time
unknown
ProviderName HP Processor