HP Insight Management WBEM Providers 9.1 for Windows Server 2008 Data Sheet

Table 1-20 HP_ProcessorHardwareIndication: Processor Failed
Property name Property implementation
IndicationTime Time of indication
CIM_AlertIndication
Description Processor has failed
AlertingManagedElement WBEM path of the HP_ProcessorChip instance
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 1
ProviderName HP Processor
RecommendedActions Replace the failed Processor.
SystemName HP_ComputerSystem.SystemName
SystemCreationClassName HP_ComputerSystem.CreationClassName
HP_AlertIndication
Summary Processor failed
EventCategory 2 (Processor)
ProbableCause 1 (Other)
ProbableCauseDescription Processor has failed
ProviderVersion Provider version generating the indication in the
format,
<major>.<minor>.<revision>.<build>
NetworkAddresses Contains a list of all the IP addresses (IPv4 and IPv6) of
the computer system generating the indication
OSType
For Windows 2003 32-bit: 69
For Windows 2003 64-bit: 70
For Windows 2008 32-bit: 76
For Windows 2008 64-bit: 77
For Windows 2008 R2: 103
OSVersion Operating system version of the computer system
generating the indication in the format,
<major>.<minor>.<build>
SystemFirmwareVersion Firmware version of the computer system generating
the indication
SystemSerialNumber Serial number of the computer system generating the
indication
SystemProductID Product ID of the computer system generating the
indication
SystemModel Model name of the computer system generating the
indication
SystemGUID Platform GUID of the computer system generating the
indication