HP Insight Management WBEM Providers 9.1 for Windows Server 2008 Data Sheet
Table 1-72 HPSCSI_DeviceIndication: Controller status ERROR
Property name
Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at indication
PerceivedSeverity
6 (Critical)
IndicationTime Time of indication
CIM_AlertIndication
Description SCSI HBA has failed and is no longer operating
AlertingMangedElement WBEM path of the HPSCSI_HBAComputerSystem class
instance
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 3
ProviderName HP SCSI
RecommendedActions Replace this HBA.
SystemName Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary
This SCSI HBA has failed
EventCategory 11 (I/O Adapter)
ProbableCause 1 (other)
ProbableCauseDescription
SCSI HBA Status Changed to Error
ProviderVersion Provider version generating the indication in the
format, <major>.<minor>.<revision>.<build>
NetworkAddresses Contains a list of all the IP addresses (IPv4 and IPv6) of
the computer system generating the indication
OSType
•
For Windows 2003 32-bit: 69
•
For Windows 2003 64-bit: 70
•
For Windows 2008 32-bit: 76
•
For Windows 2008 64-bit: 77
•
For Windows 2008 R2: 103
OSVersion Operating system version of the computer system
generating the indication in the format,
<major>.<minor>.<build>
SystemFirmwareVersion Firmware version of the computer system generating
the indication