HP Insight Management WBEM Providers 9.1 for Windows Server 2008 Data Sheet

Table 1-133 HPSA_DeviceIndication: Enclosure Temperature sensor status changed to Warning
Property name
Property implementation
HP_DeviceIndication
DeviceModel Enclosure Model string
15-4-26 Enclosure Temperature sensor Status Changed
to Critical
Table 1-134
HPSA_DeviceIndication: Enclosure Temperature sensor status changed to Critical
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at indication
PerceivedSeverity 5 (major)
IndicationTime Time of indication
CIM_AlertIndication
Description Temperature sensor Status changed to a status of
Critical. Enclosure temperature is reaching maximum
allowed temperature for normal operation, shutdown is
imminent. Action is required before loss of data occurs.
AlertingMangedElement
WBEM path of the HPSA_StorageEnclosureProcessor
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID
309
ProviderName HP Smart Array
RecommendedActions Verify fan and power supply operation for enclosure.
Verify ambient room temperature is within guidelines.
SystemName Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary Temperature sensor Status changed to Critical.
EventCategory
24 (Primary Storage Cooling)
ProbableCause 51 (Temperature Unnacceptable)
NetworkAddresses Contains a list of all the IP addresses (IPv4 and IPv6) of
the computer system generating the indication