HP Insight Management WBEM Providers 9.1 for Windows Server 2008 Data Sheet
Table 1-129 HPSA_DeviceIndication: Enclosure Power Supply status changed to Non Redundant
Property name
Property implementation
ImpactedDomain
•
3 (Enclosure) for c-Class BladeSystems
•
4 (System) for all other systems
When ImpactedDomain is 3 (Enclosure), the properties
indicated with (*) are populated.
BladeBay * HP_BladeCSLocation.LocationInformation[0]
BladeName * HP_ComputerSystem.Name
EnclosureName * HP_BladeEnclosureCS.Name
RackName * Rack name if one exists
RackUID * Rack Unique Identifier if one exists
SystemVirtualSerialNumber Conditional property containing the virtual system
serial number string when running in a Virtual Connect
environment
SystemVirtualUUID Conditional property containing the virtual system
UUID when running in a Virtual Connect environment
SolutionProductModel
Conditional property containing the Solution Name
string when running in a aggregate product
environment in the format <aggregate product family
name> v<major>.<minor>.<update>
HP_HardwareIndication
HWLogicalLocation Enclosure Location string
For example, Port 1I Box 1
HWSerialNumber Enclosure Serial Number
HP_DeviceIndication
DeviceModel Enclosure Model string
15-4-22 Enclosure Power Supply Status Changed to
OK (Redundant)
Table 1-130 HPSA_DeviceIndication: Enclosure Power Supply status changed to OK (Redundant)
Property name
Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at indication
PerceivedSeverity 2 (Info)
IndicationTime
Time of indication