Table 1-126 HPSA_DeviceIndication: Controller Cache status changed to OK
Property name
Property implementation
ImpactedDomain
3 (Enclosure) for c-Class BladeSystems
4 (System) for all other systems
When ImpactedDomain is 3 (Enclosure), the properties
indicated with (*) are populated.
BladeBay * HP_BladeCSLocation.LocationInformation[0]
BladeName * HP_ComputerSystem.Name
EnclosureName * HP_BladeEnclosureCS.Name
RackName * Rack name if one exists
RackUID * Rack Unique Identifier if one exists
SystemVirtualSerialNumber Conditional property containing the virtual system
serial number string when running in a Virtual Connect
environment
SystemVirtualUUID Conditional property containing the virtual system
UUID when running in a Virtual Connect environment
Solutio
nProductModel
Conditional property containing the Solution Name
string when running in a aggregate product
environment in the format <aggregate product family
name> v<major>.<minor>.<update>
HP_HardwareIndication
HWFirmwareVersion Array Controller firmware version string
HWLogicalLocation Array Controller Location string
For example, Smart Array P600 in Slot 5
HWManufacturer Array Controller Manufacturer string
HWSerialNumber Array Controller Serial Number
HP_DeviceIndication
DeviceModel Array Controller Model string
15-4-19 Controller Cache StatusTemporarily
Disabled
Table 1-127 HPSA_DeviceIndication: Controller Cache statusTemporarily Disabled
Property name Property implementation
CIM_Indication
IndicationIdentifier
GUID string generated at indication