HP Insight Management WBEM Providers 9.1 for Windows Server 2008 Data Sheet

Table 1-119 HPSA_DeviceIndication: Controller status changed to ERROR
Property name
Property implementation
SolutionProduct
Model
Conditional property containing the Solution Name
string when running in a aggregate product
environment in the format <aggregate product family
name> v<major>.<minor>.<update>
HP_HardwareIndication
HWFirmwareVersion Array Controller firmware version string
HWLogicalLocation Array Controller Location string
For example, Smart Array P600 in Slot 5
HWManufacturer Array Controller Manufacturer string
HWSerialNumber Array Controller Serial Number
HP_DeviceIndication
DeviceModel Array Controller Model string
15-4-12 Controller Redundancy state has been set to
Active
Table 1-120 HPSA_DeviceIndication: Controller Redundancy state has been set to ACTIVE
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at indication
PerceivedSeverity 3 (Warning)
IndicationTime Time of indication
CIM_AlertIndication
Description A Smart Array controller redundancy state has
changed from Standby to Active.
AlertingMangedElement WBEM path to the HPSA_ArrayController class.
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 3
ProviderName HP Smart Array
RecommendedActions Check status of all controllers. A controller may have
failed to cause this controller to become active.
SystemName Name of the computer system generating the indication