HP Insight Management WBEM Providers 9.1 for Windows Server 2008 Data Sheet

Table 1-118 HPSA_DeviceIndication: Controller status changed to OK
Property name
Property implementation
HP_DeviceIndication
DeviceModel Array Controller Model string
15-4-11 Controller Status Changed to ERROR
Table 1-119 HPSA_DeviceIndication: Controller status changed to ERROR
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at indication
PerceivedSeverity 5 (Major)
IndicationTime Time of indication
CIM_AlertIndication
Description Array Controller Status has changed to a status of
ERROR
AlertingMangedElement WBEM path to the HPSA_ArrayController class.
AlertingElementFormat
2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 2
ProviderName
HP Smart Array
RecommendedActions Check controller status. Run Diagnostics.
SystemName Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary Controller Status changed to Error
EventCategory 6 (Primary Storage)
ProbableCause 24 (I/O device error)
NetworkAddresses Contains a list of all the IP addresses (IPv4 and IPv6) of
the computer system generating the indication
OSType
For Windows 2003 32-bit: 69
For Windows 2003 64-bit: 70
For Windows 2008 32-bit: 76
For Windows 2008 64-bit: 77
For Windows 2008 R2: 103