HP Insight Management WBEM Providers 9.1 for Windows Server 2008 Data Sheet
Contents 128
5-4-3 Fan Failed
Table 1-21 HP_SensorHardwareIndication: Fan Failed
Property name
Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at indication
PerceivedSeverity 5 (Major)
IndicationTime Time of indication
CIM_AlertIndication
Description A fan has failed. (FanCaption), where FanCaption is the
HP_WinFan.Caption for the fan that has failed
AlertingManagedElement WBEM path of the HP_WinFan instance representing
the failed fan
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 3
ProviderName HP Cooling
RecommendedActions Check the failed fan and replace if necessary.
SystemName
HP_ComputerSystem.Name
SystemCreationClassName HP_ComputerSystem.CreationClassName
HP_AlertIndication
Summary
Fan failed
EventCategory 23 (System Cooling)
ProbableCause 94 (Fan Failure)
ProbableCauseDescription
Fan Failed
ProviderVersion Provider version generating the indication in the
format, <major>.<minor>.<revision>.<build>
NetworkAddresses Contains a list of all the IP addresses (IPv4 and IPv6) of
the computer system generating the indication
OSType
•
For Windows 2003 32-bit: 69
•
For Windows 2003 64-bit: 70
•
For Windows 2008 32-bit: 76
•
For Windows 2008 64-bit: 77
•
For Windows 2008 R2: 103
OSVersion Operating system version of the computer system
generating the indication in the following format,
<major>.<minor>.<build>