HP Insight Management WBEM Providers 9.1 for Windows Server 2008 Data Sheet
Table 2-27 HP_SensorHardwareIndication: Power Supply Repaired
Property name Property implementation
SolutionProductModel
Conditional property containing the Solution Name
string when running in a aggregate product
environment in the format <aggregate product family
name> v<major>.<minor>.<update>
HP_HardwareIndication
HWSerialNumber Conditional property containing the chassis serial
number when the chassis is a multi-node server chassis
4-4-5 Power Supply Redundancy Reduced
Table 2-28 HP_SensorHardwareIndication: Power Supply Redundancy Reduced
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at indication
PerceivedSeverity 2 (Information)
IndicationTime Time of indication
CIM_AlertIndication
Description A fault tolerant power supply is no longer providing
power for a power redundancy set.
(RedundancySetCaption), where RedundancySetCaption
represents the HP_WinPowerRedundancySet.Caption
for the redundancy set with reduced redundancy.
AlertingManagedElement WBEM path of the HP_WinPowerRedundancySet
instance representing the redundancy set with reduced
redundancy.
AlertingElementFormat
2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 5
ProviderName
HP Power
RecommendedActions No action is recommended.
SystemName HP_ComputerSystem.Name
SystemCreationClassName
HP_ComputerSystem.CreationClassName
HP_AlertIndication
Summary Power redundancy reduced
EventCategory 16 (System Power)
ProbableCause 88 (Loss of Redundancy)
ProbableCauseDescription Power Redundancy Reduced