HP Insight Management WBEM Providers 9.1 for Windows Server 2008 Data Sheet

Table 2-26 HP_SensorHardwareIndication: Power Supply Failed
Property name Property implementation
SystemVirtualSerialNumber Conditional property containing the virtual system
serial number string when running in a Virtual Connect
environment
SystemVirtualUUID Conditional property containing the virtual system
UUID when running in a Virtual Connect environment
SolutionProductModel
Conditional property containing the Solution Name
string when running in a aggregate product
environment in the format <aggregate product family
name> v<major>.<minor>.<update>
HP_HardwareIndication
HWSerialNumber Conditional property containing the chassis serial
number when the chassis is a multi-node server chassis
4-4-4 Power Supply Repaired
Table 2-27 HP_SensorHardwareIndication: Power Supply Repaired
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at indication
PerceivedSeverity 2 (Information)
IndicationTime Time of indication
CIM_AlertIndication
Description A power supply has been repaired.
(PowerSupplyCaption), where PowerSupplyCaption is the
HP_WinPowerSupply. Caption for the power supply
that has been repaired.
AlertingManagedElement WBEM path of the HP_WinPowerSupply instance
representing the failed power supply
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 4
ProviderName HP Power
RecommendedActions No action is recommended.
SystemName HP_ComputerSystem.Name
SystemCreationClassName HP_ComputerSystem.CreationClassName
HP_AlertIndication
Summary Power Supply repaired