HP Insight Management WBEM Providers 9.0 for Windows Server 2003/2008 Event Log Messages Reference Guide

Table 2 Insight Provider Indications for Version 9.0 (continued)
Windows
Event ID
(short)
Windows
Event ID (full)
Windows
Event
Source
DescriptionSummaryEvent IDProvider Name
changed from
non-OK to OK.
101073741834
HP Smart
Array
A Smart Array
controller Cache
Array
controller
10
HP Smart
Array
status has
cache status
changed to
temporarily
disabled
Temporarily
Disabled. This
may be caused by
a rebuild or
configuration
change. Normal
operation will
return after
background
operations have
completed.
112147483659
HP Smart
Array
A Smart Array
controller Cache
Array
controller
11
HP Smart
Array
status has
cache status
changed to
permanently
disabled
Permanently
Disabled. The
controller has
detected a
problem with the
cache and has
disabled the
cache
permanently.
122147483660
HP Smart
Array
A Smart Array
controller Cache
Array
controller
12
HP Smart
Array
status has
cache status
changed to not
not
configured
configured. This
may be caused by
a configuration
change.
1011073741925
HP Smart
Array
A logical drive
status has
Logical drive
status OK101
HP Smart
Array
changed from a
non-OK state to
OK.
1023221225574
HP Smart
Array
A logical drive
status has
changed to Error.
Logical drive
status error102
HP Smart
Array
1032147483751
HP Smart
Array
A logical drive is
in a degraded
Logical drive
in degraded
state103
HP Smart
Array
state. Device is
still servicing I/O
but redundancy
may be degraded
or lost.
1042147483752
HP Smart
Array
A logical drive is
in a degraded
Logical drive
in degraded
104
HP Smart
Array state. Multipathstate -
23