HP Insight Management WBEM Providers 9.0 for Windows Server 2003/2008 Event Log Messages Reference Guide
Table 2 Insight Provider Indications for Version 9.0 (continued)
Windows
Event ID
(short)
Windows
Event ID (full)
Windows
Event
Source
DescriptionSummaryEvent IDProvider Name
3093221225781HP SAS
A Storage
Enclosure
Temperature
sensor status
Critical309HP SAS
Temperature
sensor status has
changed to
Critical. An
enclosure
temperature is
reaching the
maximum allowed
temperature for
normal operation.
A shutdown is
imminent. Action
is required before
loss of data
occurs.
6001073742424HP SATA
A new disk drive
was detected.
New Disk
Drive found600HP SATA
6011073742425HP SATA
A Disk Drive status
has changed to
Unknown.
Disk Drive
status
unknown601HP SATA
6021073742426HP SATA
A Disk Drive status
has changed to
OK.
Disk Drive
status OK602HP SATA
6033221226075HP SATA
A Disk Drive status
has changed to
'Error'.
Disk Drive
status error603HP SATA
6042147484252HP SATA
A Disk Drive status
has changed to
'Degraded'.
Disk Drive
status
degraded604HP SATA
6052147484253HP SATA
A physical drive
status has
Physical drive
status
605HP SATA
changed to
Predictive
Failure.
Predictive Failure.
Drive is
functioning
nominally but
predicting a
failure in the near
future.
6133221226085HP SATA
A Disk Drive
disappeared from
system.
Disk Drive
Missing613HP SATA
11073741825HP SCSI
A SCSI device
status hasSCSI device
status
unknown1HP SCSI
changed to
Unknown.
21073741826HP SCSI
This SCSI HBA
status has
SCSI HBA
status OK2HP SCSI
changed from
non-OK to OK.
19