HP Insight Management WBEM Providers for Windows Server 2003/2008 Version 9.
© Copyright 2011 Hewlett-Packard Development Company, L.P Legal Notices Confidential computer software. Valid license required from Hewlett-Packard for possession, use or copying. Consistent with FAR 12.211 and 12.212, Commercial Computer Software, Computer Software Documentation, and Technical Data for Commercial Items are licensed to the U.S. Government under vendor’s standard commercial license. The information contained herein is subject to change without notice.
Contents 1 2 3 4 5 6 7 Glossary...................................................................................................4 Introduction...............................................................................................5 Related Documents.....................................................................................6 Indication to Eventlog Mapping....................................................................7 Sample Indication and Log Message.................................
1 Glossary Table 1 Acronyms 4 Terms Definition CIM Common Information Model CIMOM CIM Object Manager COM Component Object Model DLL Dynamic Link Library DMTF Distributed Management Task Force OS Operating System TC Technical Committee WBEM Web-Based Enterprise Management Glossary
2 Introduction This document contains a list of the Windows Eventlog messages generated by the HP Insight Management WBEM Providers for Windows Server 2003/2008. Each alert indication from the \root\HPQ namespace conforming to the query “SELECT * FROM HP_AlertIndication” will be logged to the Windows System Event Log. Each threshold indication from the \root\HPQ namespace conforming to the query “SELECT * FROM HP_ThresholdIndication” will also be logged to the Windows System Event Log.
3 Related Documents The purpose of this document is to show all indications and the associated event log messages that would be logged to the Windows System Event Log. The document titled “HP Insight Management WBEM Provider Data Sheet” will document all indications and list the properties delivered by each indication.
4 Indication to Eventlog Mapping The CIM_AlertIndication.EventID and CIM_AlertIndication.ProviderName properties are unique for each type of alert indication within the system. The EventID and ProviderName properties are used to map to specific messages logged to the Windows System Event Log. The same applies for the CIM_ThresholdIndication.EventID and CIM_ThresholdIndication.ProviderName.
5 Sample Indication and Log Message Here is a sample of a Windows Event Log message from an indication with a Source of “HP Sensor” and an Event ID of “6”. Figure 2 Windows Event Log message Description expanded from above: Cooling redundancy has been lost. (Cooling Redundancy Set 1) User Action Check the fan configuration and check the status of the cooling redundancy. Ensure the system is being cooled adequately. Add or replace fans if necessary.
SystemModel: "ProLiant DL380 G5" SystemName: "arsenal" SystemProductID: "417455-001" SystemSerialNumber: "XXX12345678" TIME_CREATED: 128505106099687502 0x1c88ab690e5504e 9
6 Suggested Event Log Scraping Method The suggested method to perform Event Log scraping of actionable events is to use the “Source” and “Event ID” of the Event log message to determine the specific type of event that occurred. It is not recommended to parse the event log message text to determine the event type that occurred.
7 List of HP Insight Provider Indications The following table documents the list of indications and corresponding Windows Event Log messages for version 9.0 of the HP Insight Management WBEM Providers. Table 2 Insight Provider Indications for Version 9.0 Provider Name Event ID Summary HP Cooling 1 A fan has been Fan removed removed. (%s) HP Sensor 1073741825 1 HP Cooling 2 Fan inserted A fan has been inserted. (%s) HP Sensor 1073741826 2 HP Cooling 3 Fan failed A fan has failed.
Table 2 Insight Provider Indications for Version 9.0 (continued) Provider Name Event ID Summary HP Disk Threshold 2 The Disk utilization warning Disk warning threshold has threshold exceeded for HP Disk exceeded Disk:(%s). Threshold 2147483649 1 1 An Ethernet provider Event encountered an provider fatal unrecoverable error error.
Table 2 Insight Provider Indications for Version 9.0 (continued) Provider Name Event ID Summary Description Windows Windows Windows Event Event ID (full) Event ID Source (short) is an optional indication that can be disabled via the Ethernet Event Provider settings. HP Ethernet HP Ethernet HP Ethernet HP Ethernet HP Ethernet 8 A team member was dropped from the team via the HP Network Configuration Utility (NCU).
Table 2 Insight Provider Indications for Version 9.0 (continued) Provider Name Event ID Summary HP Ethernet 13 The number of active adapters in an Ethernet team Ethernet team has changed. This reported is an optional change in indication that can number of be disabled via active the Ethernet Event HP members Provider settings. Ethernet 1073741837 13 14 Provider cannot access data source The event provider encountered a non-fatal error. Some information may not be HP available.
Table 2 Insight Provider Indications for Version 9.0 (continued) Provider Name Event ID Summary Description Windows Windows Windows Event Event ID (full) Event ID Source (short) to a loop back state. HP Memory 1 Memory module has failed or is predicted to fail HP Memory 2 Memory board error A memory board HP has an error. (%s) Memory 3221225474 Advanced Memory Protection degraded The Advanced Memory Protection (AMP) system is operating with degraded redundancy.
Table 2 Insight Provider Indications for Version 9.0 (continued) Provider Name Event ID Summary Description Windows Windows Windows Event Event ID (full) Event ID Source (short) occurred during the last system startup. 1 A power supply Power supply has been removed removed. (%s) HP Sensor 1073742825 1001 HP Power 2 A power supply Power supply has been inserted. HP inserted (%s) Sensor 1073742826 1002 HP Power 3 Power supply A power supply failed has failed.
Table 2 Insight Provider Indications for Version 9.0 (continued) Provider Name Event ID Summary Description HP Recovery Thermal reboot occurred The system has rebooted from a thermal shutdown HP event. System 3221225474 2 1 HBA status OK A SAS/SATA HBA status has changed from non-OK to OK. HP SAS 1073741825 1 2 HBA status Error A SAS/SATA HBA status has changed to Error. HP SAS 3221225474 2 101 A logical drive status has Logical Drive changed from status OK non-OK to OK.
Table 2 Insight Provider Indications for Version 9.0 (continued) Provider Name Event ID Summary Description Windows Windows Windows Event Event ID (full) Event ID Source (short) changed to Fully Redundant. HP SAS HP SAS HP SAS HP SAS HP SAS HP SAS 18 303 304 305 306 307 308 A Storage Enclosure Power Power supply Supply status has status changed to Redundant Degraded Degraded Redundancy.
Table 2 Insight Provider Indications for Version 9.0 (continued) Provider Name Event ID Summary Description Windows Windows Windows Event Event ID (full) Event ID Source (short) A Storage Enclosure Temperature sensor status has changed to Critical. An enclosure temperature is reaching the maximum allowed temperature for normal operation. A shutdown is imminent. Action is required before loss of data occurs.
Table 2 Insight Provider Indications for Version 9.0 (continued) Provider Name Event ID Summary Description HP SCSI 3 SCSI HBA status error A SCSI HBA status has changed to Error. HP SCSI 4 A SCSI physical drive status has Physical drive changed from OK non-OK to OK. HP SCSI 1073741828 5 A SCSI physical Physical drive drive has a status Error of Error.
Table 2 Insight Provider Indications for Version 9.0 (continued) Provider Name Event ID Summary Description Windows Windows Windows Event Event ID (full) Event ID Source (short) changed to Fully Redundant. HP SCSI HP SCSI HP SCSI HP SCSI HP SCSI HP SCSI HP SCSI 303 304 305 306 307 308 309 A Storage Enclosure Power Power supply Supply status has status changed to Redundant Degraded Degraded Redundancy.
Table 2 Insight Provider Indications for Version 9.0 (continued) Provider Name Event ID Summary Description Windows Windows Windows Event Event ID (full) Event ID Source (short) temperature for normal operation. A shutdown is imminent. Action is required before loss of data occurs.
Table 2 Insight Provider Indications for Version 9.0 (continued) Provider Name Event ID Summary Description Windows Windows Windows Event Event ID (full) Event ID Source (short) changed from non-OK to OK. HP Smart Array HP Smart Array HP Smart Array HP Smart Array HP Smart Array HP Smart Array HP Smart Array Array controller cache status temporarily disabled A Smart Array controller Cache status has changed to Temporarily Disabled. This may be caused by a rebuild or configuration change.
Table 2 Insight Provider Indications for Version 9.0 (continued) Provider Name Event ID HP Smart Array HP Smart Array HP Smart Array HP Smart Array HP Smart Array HP Smart Array HP Smart Array HP Smart Array HP Smart Array 24 Summary Description multipath failure support is Lost. Either cable is removed or not configured. 201 Physical Drive status OK A physical drive status has changed from a non-OK state to OK. 202 A physical drive Physical drive status has status Error changed to Error.
Table 2 Insight Provider Indications for Version 9.0 (continued) Provider Name Event ID HP Smart Array HP Smart Array HP Smart Array HP Smart Array HP Smart Array HP Smart Array 304 305 306 307 308 309 Summary Description Windows Windows Windows Event Event ID (full) Event ID Source (short) Fan status OK A Storage Enclosure Fan status has changed from a non-OK state to OK. HP Smart Array 1073742128 304 Fan status Degraded A Storage Enclosure Fan status has changed to Degraded.
Table 2 Insight Provider Indications for Version 9.0 (continued) Provider Name Event ID Summary Description Windows Windows Windows Event Event ID (full) Event ID Source (short) maximum allowed temperature for normal operation. A shutdown is imminent. Action is required before loss of data occurs. 311 Due to Solid State wear out a physical drive Physical drive status has status changed to Predictive Predictive Failure HP Smart Failure .
Table 2 Insight Provider Indications for Version 9.0 (continued) Provider Name Event ID Summary Description HP Tape 510 Tape drive missing was 'Degraded' A tape drive with a 'Degraded' status has been removed. HP Tape 1073742334 510 511 Tape drive cleaning required Tape drive heads need cleaning. HP Tape 3221225983 511 512 Cleaning tape replacement required A fully used cleaning tape has been detected.