HP Insight Management WBEM Providers 9.0 for Windows Server 2003 and Windows Server 2008 Data Sheet

Table 4-11 Class: HP_PowerSupplySlot
Property name
Property implementation
CIM_PhysicalElement
CreationClassName “HP_PowerSupplySlot”
Tag Power Supply n, where n represents the physical bay
number
Description Power Supply n, where n represents the physical bay
number
ElementName Power Supply n, where n represents the physical bay
number
CIM_PhysicalConnector
ConnectorLayout 7 (Slot)
ConnectorPinout “Custom Power Bay”
ConnectorType 76 (Proprietary)Custom Power Supply slot
CIM_Slot
Number The physical power supply bay number
SupportsHotPlug
Trueif slot supports hot plug operations
Falseif slot does not support hot plug operations
VendorCompatibilityStrings
“HPQ:PowerSupply”
HP_PowerSupplySlot
4-3-11 HP_PowerSupplyInSlot
HP_PowerSupplyInSlot is used to represent an association between HP_PowerSupplyModule and
HP_PowerSupplySlot that contains this Power Supply.
Table 4-12 Class: HP_PowerSupplyInSlot
Property name Property implementation
Antecedent References HP_PowerSupplySlot
Dependent References HP_PowerSupplyModule
4-3-12 HP_RealizesPowerSupply
HP_RealizesPowerSupply is used to represent an association between HP_PowerSupply and
HP_PowerSupplyModule that realizes this power supply.