HP Insight Management WBEM Providers 9.0 for Windows Server 2003 and Windows Server 2008 Data Sheet

Table 4-10 Class: HP_PowerSupplyModule
Property name
Property implementation
CreationClassName “HP_PowerSupplyModule
PartNumber The spare part number for the power supply (if
available)
Tag Unique identifier for this power supply module instance
CIM_PhysicalPackage
PackageType 6 (Power Supply)
RemovalConditions 3 (Removable when off)
4 (Removable when on or off)
HP_PowerSupplyModule
4-3-10 HP_PowerSupplySlot
HP_PowerSupplySlot represents power supply bays on ProLiant Servers. An instance of this class
occurs for each power supply bay in the system, whether or not the bay is occupied.
Table 4-11 Class: HP_PowerSupplySlot
Property name Property implementation
CIM_ManagedElement
Caption Power Supply n, where n represents the physical bay
number
CIM_Managed SystemElement
HealthState
0 (Unknown)—Power supply unknown or not
present
5 (OK)If power supply is operating properly;
20 (Major Failure) if power supply has failed
Name Power Supply n, where n represents the physical bay
number
OperationalStatus[0]
0 (Unknown)Power supply unknown or not
present
2 (OK)—If power supply is operating properly or
no power supply in the bay
6 (Error)If power supply has failed
StatusDescriptions[0]
“Power Supply status unknown”If
OperationalStatus[0] is 0 (Unknown)
“Power Supply is operating properly”If
OperationalStatus[0] is 2 (OK)
“Power Supply has failed”IfOperationalStatus is
6 (Error)