HP Insight Management WBEM Providers 9.0 for Windows Server 2003 and Windows Server 2008 Data Sheet
<major>.<minor>.<build>
ProviderVersion Provider version generating the indication in the
format, <major>.<minor>.<revision>.<build>
Summary Disk Warning threshold exceeded
SystemModel Model name of the computer system generating the
indication
SystemProductID Product ID of the computer system generating the
indication
SystemSerialNumber Serial number of the computer system generating the
indication
HP_DiskThresholdIndication
2-4-13 Threshold Indication - Disk Utilization Critical Threshold
Exceeded
Table 2-15 HP_ThresholdIndication: Disk Utilization Critical Threshold Exceeded
Property name Property implementation
CIM_Indication
IndicationIdentifier
GUID string generated at indication
PerceivedSeverity
5 (Major)
IndicationTime
Time of indication
CIM_AlertIndication
Description The Disk utilization critical threshold has exceeded for
Disk:(Disk Name)
AlertingElementFormat 1 (Unknown)
AlertType 1 0x1 (Other)
EventID 1
ProviderName HP Disk Threshold
RecommendedActions None
SystemName HP_ComputerSystem.Name
SystemCreationClassName HP_ComputerSystem.CreationClassName
ProbableCause 1 0x1 (Other)
ProbableCauseDescription Disk critical threshold exceeded
SystemFirmwareVersion Firmware version of the computer system generating
the indication
SystemGUID Platform GUID of the computer system generating the
indication
ImpactedDomain
•
3 (Enclosure) for c-Class BladeSystems
•
4 (System) for all other systems
When ImpactedDomain is 3 (Enclosure), the
properties indicated with (*) are populated.
BladeBay * HP_BladeCSLocation.LocationInformation[0]