HP Insight Management WBEM Providers 9.0 for Windows Server 2003 and Windows Server 2008 Data Sheet
Table 18-77 HPSCSI_DeviceIndication: Temperature sensor status change Warning Condition
Property name
Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at indication
PerceivedSeverity
4 (Minor)
IndicationTime Time of indication
CIM_AlertIndication
Description The SCSI Storage enclosure temperature is outside of
normal operating range
AlertingMangedElement WBEM path of the HPSCSI_StorageEnclosureProcessor
class instance
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID
24
ProviderName HP SCSI
RecommendedActions Ensure server cover is properly installed. Ensure all
empty disk drive bays are filled with drive covers.
SystemName Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary This SCSI Storage enclosure temperature status is
Warning
EventCategory 24 (Primary Storage Cooling)
ProbableCause 51 (Temperature unacceptable)
ProbableCauseDescription Temperature Status Changed to Warning Condition
ProviderVersion Provider version generating the indication in the
format,
<major>.<minor>.<revision>.<build>
NetworkAddresses Contains a list of all the IP addresses (IPv4 and IPv6) of
the computer system generating the indication
OSType
•
For Windows 2008 32-bit: 76
•
For Windows 2008 64-bit: 77
•
For Windows 2008 R2: 103
OSVersion Operating system version of the computer system
generating the indication in the format,
<major>.<minor>.<build>
SystemFirmwareVersion Firmware version of the computer system generating
the indication