HP Insight Management WBEM Providers 9.0 for Windows Server 2003 and Windows Server 2008 Data Sheet

Table 18-75 HPSCSI_DeviceIndication: Power Supply status DEGRADED
Property name
Property implementation
IndicationIdentifier GUID string generated at indication
PerceivedSeverity 3 (Warning)
IndicationTime Time of indication
CIM_AlertIndication
Description One of the component power supplies that make up
the redundant power supply has failed. The drive
system (either a drive subsystem or a power supply for
the main unit) continues to operate. However, if the
remaining power supply should fail, the drive system
will lose all power and data loss could occur
AlertingMangedElement WBEM path of the HPSCSI_StorageEnclosureProcessor
class instance
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 20
ProviderName HP SCSI
RecommendedActions Schedule replacement of redundant power supply
SystemName
Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary SCSI Storage enclosure redundant power supply
degraded.
EventCategory
17 (Primary Storage Power)
ProbableCause 89 (Power Supply Failure)
ProbableCauseDescription Redundant Power Supply Degraded
ProviderVersion Provider version generating the indication in the
format,
<major>.<minor>.<revision>.<build>
NetworkAddresses Contains a list of all the IP addresses (IPv4 and IPv6) of
the computer system generating the indication
OSType
For Windows 2008 32-bit: 76
For Windows 2008 64-bit: 77
For Windows 2008 R2: 103
OSVersion Operating system version of the computer system
generating the indication in the format,
<major>.<minor>.<build>
SystemFirmwareVersion Firmware version of the computer system generating
the indication