HP Insight Management WBEM Providers 9.0 for Windows Server 2003 and Windows Server 2008 Data Sheet
Table 18-69 HPSCSI_DeviceIndication: Physical Drive status—Missing was OFFLINE
Property name
Property implementation
SystemGUID Platform GUID of the computer system generating the
indication
ImpactedDomain
•
3 (Enclosure) for c-Class BladeSystems
•
4 (System) for all other systems
When ImpactedDomain is 3 (Enclosure), the properties
indicated with (*) are populated.
BladeBay * HP_BladeCSLocation.LocationInformation[0]
BladeName * HP_ComputerSystem.Name
EnclosureName * HP_BladeEnclosureCS.Name
RackName * Rack name if one exists
RackUID *
Rack Unique Identifier if one exists
SystemVirtualSerialNumber Conditional property containing the virtual system
serial number string when running in a Virtual Connect
environment
SystemVirtualUUID Conditional property containing the virtual system
UUID when running in a Virtual Connect environment
SolutionProductModel
Conditional property containing the Solution Name
string when running in a aggregate product
environment in the format <aggregate product family
name> v<major>.<minor>.<update>
HP_HardwareIndication
HWFirmwareVersion Disk firmware version string
HWLogicalLocation Disk Location string
HWManufacturer Disk Manufacturer string
HWSerialNumber Disk Serial Number
HP_DeviceIndication
DeviceModel Disk Model string
17-4-9 Controller Status change—Unknown
Table 18-70 HPSCSI_DeviceIndication: Controller status changed to Unknown
Property name
Property implementation
CIM_Indication