HP Insight Management WBEM Providers 9.0 for Windows Server 2003 and Windows Server 2008 Data Sheet

Table 17-84 HPSAS_DeviceIndication: Enclosure Temperature sensor status changed to Warning
Property name
Property implementation
SystemVirtualUUID Conditional property containing the virtual system
UUID when running in a Virtual Connect environment
SolutionProductModel
Conditional property containing the Solution Name
string when running in a aggregate product
environment in the format <aggregate product family
name> v<major>.<minor>.<update>
HP_HardwareIndication
HWLogicalLocation Enclosure Location string
For example, Port 1I Box 1
HWSerialNumber Enclosure Serial Number
HP_DeviceIndication
DeviceModel Enclosure Model string
16-4-15 Enclosure Temperature sensor Status Changed to
Critical
Table 17-85 HPSAS_DeviceIndication: Enclosure Temperature sensor status changed to Critical
Property name
Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at the time of indication
PerceivedSeverity 5 (major)
IndicationTime Time of indication
CIM_AlertIndication
Description A Storage Enclosure Temperature sensor status has
changed to Critical. An enclosure temperature is
reaching the maximum allowed temperature for normal
operation. A shutdown is imminent. Action is required
before loss of data occurs.
AlertingMangedElement WBEM Path of HPSAS_StorageEnclosureProcessor
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 309
EventTime Time of the event or time of the indication if event time
unknown