HP Insight Management WBEM Providers 9.0 for Windows Server 2003 and Windows Server 2008 Data Sheet
Table 17-78 HPSAS_DeviceIndication: Logical Drive status ERROR
Property name
Property implementation
ImpactedDomain
•
3 (Enclosure) for c-Class BladeSystems
•
4 (System) for all other systems
When ImpactedDomain is 3 (Enclosure), the properties
indicated with (*) are populated.
BladeBay * HP_BladeCSLocation.LocationInformation[0]
BladeName * HP_ComputerSystem.Name
EnclosureName * HP_BladeEnclosureCS.Name
RackName * Rack name if one exists
RackUID * Rack Unique Identifier if one exists
SystemVirtualSerialNumber Conditional property containing the virtual system
serial number string when running in a Virtual Connect
environment
SystemVirtualUUID Conditional property containing the virtual system
UUID when running in a Virtual Connect environment
SolutionProductModel
Conditional property containing the Solution Name
string when running in a aggregate product
environment in the format <aggregate product family
name> v<major>.<minor>.<update>
16-4-9 Logical Drive status Degraded
Table 17-79 HPSAS_DeviceIndication: Logical Drive is in a degraded state
Property name
Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at the time of indication
PreceivedSeverity 3 (Warning)
IndicationTime Time of indication
CIM_AlertIndication
Description A logical drive is in a degraded state. Device is still
servicing I/O, but redundancy may be degraded or
lost.
AlertingMangedElement WBEM Path of Storage Volume
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 103