HP Insight Management WBEM Providers 9.0 for Windows Server 2003 and Windows Server 2008 Data Sheet
Table 17-74 HPSAS_DeviceIndication: Physical Drive status ERROR
Property name
Property implementation
SolutionProductModel
Conditional property containing the Solution Name
string when running in a aggregate product
environment in the format <aggregate product family
name> v<major>.<minor>.<update>
HP_HardwareIndication
HWFirmwareVersion Disk firmware version string
HWLogicalLocation Disk Location string
For example, Bay 3
HWManufacturer Disk Manufacturer string
HWSerialNumber Disk Serial Number
HP_DeviceIndication
DeviceModel Disk Model string
16-4-5 Physical Drive status REBUILDING
Table 17-75 HPSAS_DeviceIndication: Physical Drive status REBUILDING
Property name
Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at the time of indication
PreceivedSeverity Severity
For example, 2 (Information)
IndicationTime Time of indication
CIM_AlertIndication
Description A physical drive status has changed to Rebuilding.
Data is now being rebuilt onto this drive from the RAID
set.
AlertingMangedElement WBEM Path of disk drive
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 203
EventTime Time of the event or time of the indication if event time
unknown
ProviderName
HP SAS
RecommendedActions No action is recommended.