HP Insight Management WBEM Providers 9.0 for Windows Server 2003 and Windows Server 2008 Data Sheet
Table 17-15 Class: HPSAS_StoragePool (CIM_StoragePool)
Property name
Property implementation
PoolID Controller serial number:1
Primordial FALSE
RemainingManagedSpace 0
TotalManagedSpace Total raw space managed by this pool
HPSAS_StoragePool
16-3-15 HPSAS_StorageSetting
HPSAS_StorageSetting represents the current raid configuration for a Storage Volume. There is one
instance per Storage Volume.
Table 17-16 Class: HPSAS_StorageSetting (CIM_StorageSetting)
Property name
Property implementation
CIM_ManagedElement
ElementName RAID <n>, where <n> is the raid description
•
RAID 0
•
RAID 1
CIM_SettingData
InstanceID Opaque key
CIM_StorageSetting
ChangeableType 0 (Not Changeable)
DataRedundancyGoal
•
1 (RAID 0)
•
2 (RAID 1)
DataRedundancyMax
•
1 (RAID 0)
•
2 (RAID 1)
DataRedundancyMin
•
1 (RAID 0)
•
2 (RAID 1)
DeltaReservationGoal 0
DeltaReservationMax 0
DeltaReservationMin 0
NoSinglePointOfFailure
•
FALSE—RAID 0
•
TRUE—RAID 1
PackageRedundancyGoal
•
0 (RAID 0)
•
1 (RAID 1)