HP Insight Management WBEM Providers 9.0 for Windows Server 2003 and Windows Server 2008 Data Sheet

Table 17-4 Class: HPSAS_StorageVolume (CIM_StorageVolume)
Property name
Property implementation
OperationalStatus[0] Volume status
0 (Unknown)
2 (OK)
3 (Degraded) - RAID redundancy lost or rebuilding
data
6 (Error)
CIM_LogicalElement
CIM_EnabledLogicalElement
EnabledDefault
2 (Enabled)
EnabledState 5 (Not Applicable)
RequestedState 12 (Not Applicable)
CIM_LogicalDevice
CreationClassName HPSAS_StorageVolume
DeviceID Opaque Key
SystemCreationClassName HPSAS_ArraySystem
SystemName HPSAS_ArraySystem.Name
CIM_StorageExtent
ConsumableBlocks Total Number of blocks on the volume.
BlockSize Block Size in bytes
DataRedundancy
1 (for RAID 0)
2 (for RAID 1)
DeltaReservation Set to a value of 0
ExtentStatus[0] This will indicate extended status for the volume.
2 (None)
11 (Rebuild Volume is currently rebuilding data)
IsBasedOnUnderlyingRedundancy False
NameFormat 7 (SNVM)
NoSinglePointOfFailure
TrueRAID 1 or above
FalseRAID 0
NumberOfBlocks
Total Number of blocks on the volume.
PackageRedundancy
0 (RAID 0)
1 (RAID 1)
Primordial
TRUE
FALSE (Always set this value to False)
CIM_Storagevolume