HP Insight Management WBEM Providers 9.0 for Windows Server 2003 and Windows Server 2008 Data Sheet
Table 16-58 HPSA_DeviceIndication: Controller Cache status—Permanently Disabled
Property name
Property implementation
HWFirmwareVersion Array Controller firmware version string
HWLogicalLocation Array Controller Location string
For example, Smart Array P600 in Slot 5
HWManufacturer Array Controller Manufacturer string
HWSerialNumber Array Controller Serial Number
HP_DeviceIndication
DeviceModel Array Controller Model string
15-4-21 Enclosure Power Supply Status Changed to Non
Redundant
Table 16-59 HPSA_DeviceIndication: Enclosure Power Supply status changed to Non Redundant
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at indication
PerceivedSeverity 3 (Warning)
IndicationTime Time of indication
CIM_AlertIndication
Description A Storage Enclosure Power Subsystem status has
changed to non-redundant
AlertingMangedElement WBEM path of the HPSA_StorageEnclosureProcessor
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 301
ProviderName HP Smart Array
RecommendedActions Check status of all enclosure power supplies. Problem
may be caused by a failed power supply.
SystemName Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary Power Supply Status Non-Redundant.
EventCategory 17 (Primary Storage Power)