HP Insight Management WBEM Providers 9.0 for Windows Server 2003 and Windows Server 2008 Data Sheet
Table 16-50 HPSA_DeviceIndication: Controller Redundancy state has been set to ACTIVE
Property name
Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at indication
PerceivedSeverity
3 (Warning)
IndicationTime Time of indication
CIM_AlertIndication
Description A Smart Array controller redundancy state has
changed from Standby to Active.
AlertingMangedElement WBEM path to the HPSA_ArrayController class.
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 3
ProviderName HP Smart Array
RecommendedActions Check status of all controllers. A controller may have
failed to cause this controller to become active.
SystemName
Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary Controller Redundancy State has been set to Active
EventCategory 6 (Primary Storage)
ProbableCause 0
NetworkAddresses Contains a list of all the IP addresses (IPv4 and IPv6) of
the computer system generating the indication
OSType
•
For Windows 2008 32-bit: 76
•
For Windows 2008 64-bit: 77
•
For Windows 2008 R2: 103
OSVersion Operating system version of the computer system
generating the indication in the format,
<major>.<minor>.<build>
ProviderVersion Provider version generating the indication in the
format, <major>.<minor>.<revision>.<build>
SystemFirmwareVersion Firmware version of the computer system generating
the indication
SystemSerialNumber Serial number of the computer system generating the
indication
SystemProductID Product ID of the computer system generating the
indication